“Hot Air Generator” the word itself sounds that it generates hot air. Hot air generators are widely known as “HAG”. HAG is used to heat up atmospheric air or processed air to reach desired temperature. These are widely used in most of the industries. HAG are of direct or indirect type.
Indirect Air Heaters will deliver clear uncontaminated hot air. This will avoid the use of any intermediary heating media such as Steam, Hot Water or Thermic Fluid.
PRODUCT DESCRIPTION:
SPECIFICATIONS
- Capacity ranges from 15000 kcal/hr to 600000 kcal/hr
- Fuel options LDO / Natural Gas / LPG / Coal / Wood / Briquettes / Pallets / Electricity
- Type – Direct Fired and Indirect Fired design
- Auto / Manual operation
- Control on-off / Two Stage (Low-High)
- 86% efficiency for LDO/GAS fired & 75% for Solid Fuel fired
- Easy & Economical operation
SALIENT FEATURES / KEY ATTRIBUTES / UNIQUE DESIGN FEATURES
- Clean hot air available instantly
- Compact & Robust in design
- Robust Construction and Easy Maintenance
- Simple and Safe operation
- High level of safety in operation, thus greater reliability
- Fully automatic burner control and temperature control
- Efficient performance & strong structure
HOT AIR GENERATOR | ||||||
MODEL | MI-0.3 | MI-0.6 | MI-1 | MI-2 | MI-3 | MI-6 |
CAPACITY (kcal/hr) | 30,000 | 60,000 | 1,00,000 | 2,00,000 | 3,00,000 | 6,00,000 |
MAXIMUM AIR OUTLET TEMPERATURE (°C) | 120 | 120 | 120 | 120 | 120 | 120 |
FUEL CONSUMPTION | ||||||
LDO (kg/hr) | 3.7 | 7.5 | 12 | 25 | 38 | 74 |
NATURAL GAS (m³/hr) | 4.5 | 9 | 15 | 30 | 45 | 90 |
COAL / WOOD (kg/hr) | 15 | 35 | 60 | 120 | 179 | 358 |
POWER SUPPLY | 415 VOLTS 3-PHASE 50 Hz | |||||
BURNER CONTROL | ON – OFF | ON – OFF | ON – OFF | ON – OFF | ON – OFF | ON – OFF |
APPLICATIONS
- Dyes, Chemicals and Intermediates
- Textiles industries
- Paper industries
- Printing & Packaging
- Wood / Ply wood industry
- Pharmaceutical & Drugs
- Food & Beverages
- Concrete block curing
- Paint backing applications